- Wavelength accuracy: ±0.7 ppm
- Wavelength range (3 types): 900-1700nm, 1200-1700nm, 1270-1650nm
- Measurement time of 0.2 seconds or less
- Up to 1024 wavelengths can be measured at once
- Single wavelength type and multi wavelength type
- Support modulated light and filter measurement
- Wavelength accuracy: ±0.7 ppm
- Wavelength range (3 types): 900-1700nm, 1200-1700nm, 1270-1650nm
- Measurement time of 0.2 seconds or less
- Up to 1024 wavelengths can be measured at once
- Single wavelength type and multi wavelength type
- Support modulated light and filter measurement
Item |
Specifications |
|||
Model |
AQ6150B |
AQ6151B |
||
Wavelength |
Wavelength range |
|
||
|
Standard type |
1270 nm to 1650 nm |
||
Extended type |
1200 nm to 1700 nm |
|||
Wide range type |
900 nm to 1700 nm |
|||
Wavelength accuracy1 |
|
|||
|
Standard type Extended type |
±0.7 ppm (±1 pm at 1550 nm, update rate: Normal) ±1.5 ppm (±2.3 pm at 1550 nm, update rate: Fast) |
±0.2 ppm (±0.3 pm at 1550 nm, update rate: Normal) ±0.5 ppm (±0.8 pm at 1550 nm, update rate: Fast) |
|
Wide range type |
±0.7 ppm (1200 to 1700 nm, ±1 pm at 1550 nm, update rate: Normal) ±1.5 ppm (1200 to 1700 nm, ±2.3 pm at 1550 nm, update rate: Fast) ±1.5 ppm (900 to 1200 nm, ±1.4 pm at 900 nm) |
±0.2 ppm (1200 to 1700 nm, ±0.3 pm at 1550 nm, update rate: Normal) ±0.5 ppm (1200 to 1700 nm, ±0.8 pm at 1550 nm, update rate: Fast) ±1.5 ppm (900 to 1200 nm, ±1.4 pm at 900 nm) |
||
Minimum resolvable separation2, 3 |
5 GHz (40 pm at 1550 nm, update rate: Normal) 10 GHz (80 pm at 1550 nm, update rate: Fast) |
|||
Display resolution |
0.0001 nm |
|||
Power4 |
Power accuracy5 |
±0.5 dB (1550 nm, –10 dBm) |
||
Linearity5 |
±0.3 dB (1550 nm, – 30 dBm or higher) |
|||
Polarization dependency2 |
±0.5 dB (1550 nm) |
|||
Display resolution |
0.01 dB |
|||
Maximum number of wavelengths |
1024 (-MW suffix code type) 1 (-SW suffix code type) |
|||
Minimum input power4, 6 |
|
|||
|
Standard type |
– 40 dBm (1270 to 1600 nm) – 30 dBm (1600 to 1650 nm) |
||
Extended type |
– 40 dBm (1200 to 1600 nm – 30 dBm (1600 to 1700 nm) |
|||
Wide range type |
– 40 dBm (1200 to 1600 nm) – 30 dBm (1600 to 1700 nm and 900 to 1200 nm) |
|||
Maximum input power |
+10 dBm (the power of all lines) |
|||
Safe maximum input power |
+18 dBm (the power of all lines) |
|||
Applicable optical fiber |
SM (ITU-T G.652) |
|||
Return loss2 |
35 dB |
|||
Measurement time7 |
0.3 s or less (update rate: Normal) 0.2 s or less (update rate: Fast) |
|||
Display device8 |
5.7 inch color LCD (640 x 480 dots) |
|||
Data storage Internal |
256 MB or more |
|||
|
External |
USB |
1. Line spectrum, CW, constant polarization during measurement, vacuum wavelength, input power –30 dBm or more, line separation 10 GHz or more (update rate: Normal)/20 GHz or more (update rate: Fast) in case of multi-line measurement, confidence level (k=3), excluding effects of OH base absorption.
2. Typical.
3. Excluding -SW (single-wavelength) suffix code type, equal power lines input
4. Update rate: Normal
5. Line spectrum, CW, excluding polarization effects.
6. Single line input
7. Number of detected peaks 128 or less.
8.There may be some pixels on the LCD that never light or are always lit (0.002% or less of the total number of pixels including RGB). These pixels are not defects.